Pre-completion sound testing
The building regulations establish standards that have to be achieved in the construction of buildings. Part E of the building regulations (resistance to the passage of sound) deals with requirements for sound insulation in buildings, including both new dwellings and the conversion of buildings to form dwellings.
Regulations 41 and 20 require that contractors undertake sound insulation testing for:
- Purpose-built dwelling houses and flats.
- Dwelling houses and flats formed by a change of use.
- Purpose-built rooms for residential purposes.
- Rooms for residential purposes formed by a change of use.
The 'approved documents' provide guidance for how the building regulations can be satisfied in common building situations. Section 1 of Approved document E (pre-completion testing) provides guidance on an appropriate programme of sound insulation testing for a sample of properties to verify that they comply with the building regulations.
Tests are undertaken when building work is complete (other than decoration), but without soft coverings such as carpets on the floors. Tests results are indicative of the performance of other similar properties of the same type and construction. They should be carried out on the first of each type completed, and then at least one set of tests for every further ten properties of each type, as prescribed by the building control body. A set of tests could be a total of two, four or six individual sound tests depending on the scenario.
Depending on the construction type, tests may include a number of airborne tests and impact tests. The approved procedures for testing are set out in Annex B of the approved document.
If tests are failed, remedial work should be carried out, other similar properties tested or remediated, and the rate of testing increased.
The robust details certification scheme provides an alternative to pre-completion sound testing. Users choose details from a handbook, register their plots on the scheme website prior to commencement on site, and notify building control. They must then construct the details in accordance with the handbook specification. For more infomration see: Robust details certification scheme.
[edit] Related articles on Designing Buildings Wiki
- Airborne sound.
- Approved Document E.
- BREEAM Acoustic performance.
- Building acoustics.
- Decibel.
- Noise nuisance.
- Part E compliance.
- Reverberation.
- Robust details certification scheme.
- Room acoustics.
- Sound absorption.
- Sound absorption coefficient.
- Sound frequency.
- Sound insulation in buildings.
- Sound insulation in dwellings: Part 1: An introduction (GG 83-1).
- Sound insulation in dwellings Part 2: New-build (GG 83-2)
- Sound insulation in dwellings: Part 3: Material change of use (conversions) (GG 83-3).
- Sound v noise.
- Structure-borne sound.
Featured articles
Check out some of the best features and news from Designing Buildings as well as key stories from around the web.
Electrical contractors need to understand the practical implications.
The real barrier to getting more value from digital technology.
Your guide to The Construction Reset at UKCW Birmingham.
Accommodating the Victorian and Edwardian working woman. Book review.
Rethinking passive fire protection in design
PFP demands the same level of design rigour as structure or services.
38% of Gen Zs feel safe when a fire door is wedged open.
Stunning images from around the world
Shortlist for CIOB’s Art of Building photography competition.
Guidance for conversion of traditional pre-1919 stone buildings.
Industrial heritage in the Ruhr
A marked difference to the fate of industrial landscapes in the UK.
Communities will be able to build their own clean energy.
Why diversity and inclusion matters for SMEs
CIOB’s D&I Charter shows how practical changes can support long-term growth.
Cut electricity bills to power growth
Coalition sends joint letter to the Chancellor.